الاثنين–الجمعة 9:00–18:00 · التوقيت الصيني القياسي (UTC+8) · شاندونغ، الصين
Quality & Testing

Built, Inspected and Documented

Laminated busbar quality is determined long before the first electrical test — it is built into the layup, the lamination window and the terminal welding.

Manufacturing Process

Eight controlled steps from copper sheet to tested part

Material PreparationCopper (C11000) or aluminum inspected for thickness tolerance
Punching & Laser CuttingConductor profiles, holes and windows cut to drawing
Surface FinishingTin plating for corrosion resistance and joint solderability
Dielectric LayupPET, Nomex or epoxy films by voltage class
LaminationHeat and pressure held to recipe; dielectric thickness in tolerance
Edge SealingExposed dielectric layers cannot creep or arc
Terminal AssemblyStuds, blade tabs and fused links welded in position
CNC Trim & InspectionFinal dimensional verification against the released drawing
المواد الواردة

ما يدخل في التركيب

MaterialStandard options
ConductorsC11000 copper as standard; aluminum available on request
DielectricsPET, Nomex and epoxy (DLF) films, selected by voltage class and operating temperature
PlatingTin finish for corrosion protection and joint solderability
13+سنوات منذ 2012
1–6+طبقات موصلة
~1000 Aالسعة التيارية
يوم واحدالرد التقني
الاختبار والفحص

كل دفعة إنتاج تُتحقق قبل التعبئة

Dielectric Withstand (Hipot)

Per customer specification and applicable standard.

Insulation Resistance

Measured on sampled parts per lot.

Dimensional Inspection

Terminal positions, hole sizes and envelope vs drawing.

Visual Inspection

Plating coverage, edge sealing and weld quality.

Continuity Check

Electrical verification of each conductor path.

التوثيق

سجلات يمكنك تدقيقها

تُحفظ سجلات الأبعاد والكهرباء لكل دفعة إنتاج ويمكن توفيرها مع شحنتك عند الطلب.

  • Batch test records per production lot
  • Certificates of Conformance (CoC) on request
  • PPAP-style documentation aligned at quotation
  • Test records aligned with your quality system
Inspection and test bench
تصميم لقابلية التصنيع

مكتشف مبكراً، مصلح بتكلفة منخفضة

قبل قطع أي قالب، يجري مهندسونا مراجعة DFM لرسمك – عدد الطبقات، مسارات التيار، تباعد الأطراف، مسافات الحواف وخلوص العازل. اكتشاف مسافة حافة ضيقة أو منطقة لحام صغيرة في هذه المرحلة أرخص بكثير من اكتشافها في الإنتاج.

01

Layer count

Stack-up validated against voltage class and current.

02

Current paths

Cross-sections checked against continuous and peak current.

03

Terminal spacing

Pitch and weld zones matched to mating hardware.

04

Edge distances

Creepage and dielectric clearances verified before tooling.

Standards Our Customers Reference: How They Shape the Design

Our in-house QC process — hipot, insulation resistance, dimensional, visual and continuity checks on every lot — is the internal half of quality. The external half is the standards landscape our customers design to, and it is worth being explicit about which standards apply to power-interconnect parts and how they show up in the drawings we build to.

POWER DISTRIBUTION
UL 1977

Component assemblies used in power distribution, including high-current connectors.

CANADIAN COUNTERPART
CSA C22.2 No. 182.3

Sits alongside UL 1977 on recognized connectorized power-distribution assemblies.

FLAMMABILITY
UL 94 V-0

Routine expectation for insulator housings and dielectric systems on shipped parts.

ENVIRONMENTAL
RoHS / REACH

Baseline on shipped product; halogen-free constructions available where the spec calls for it.

Application-level standards: SAE J1772 · EV charging couplersOpen-rack platform specs · in-rack busbar interfaces — these set the current-interruption, arcing and cycle-life tests the interconnect must pass.

Partial discharge cutaway of a laminated busbar edge seal

What this means for a laminated busbar

  • Creepage & clearance follow the voltage class implied by the referenced standard.
  • Edge sealing & dielectric selection are driven by the partial-discharge expectations of the test specification.
  • Terminals & contact lands are sized against the standard’s temperature-rise and hot-swap requirements.

We do not hold aerospace or defense qualifications ourselves — and we do not claim to — but customers in those programs routinely flow down their own standards and special-process requirements to the parts we build.

These standards are frequently referenced by our customers. We build to the drawing and test specification provided, and every released batch ships with its own hipot, insulation-resistance and continuity records.

Two technical references explain the physics behind the tests we run:

التزامات الجودة

موثق، دفعة تلو دفعة

تُبنى الجودة في التكوين، وفي نافذة الرققة، وفي لحام الأطراف – ثم تُتحقق وتُسجل.

مراجعة DFM قبل تصنيع الأدواترقابة جودة داخلية لكل دفعة إنتاجسجلات اختبار الدُفعات عند الطلبوثائق بنمط CoC / PPAP
موارد هندسية

تعمق أكثر

دليل تصميم القضبان المدمجة

البنية واختيار العازل وأساسيات القدرة التيارية.

اقرأ دليل التصميم

مخطط سعة التيار للقضبان

تقييمات نحاس مع خفض التصنيف.

عرض مخطط النحاس

Documented, batch by batch.

Dimensional and electrical test records per lot — CoC and PPAP-style documentation aligned at quotation.

الأسئلة الشائعة

أسئلة متكررة

إجابات مباشرة من فريق الهندسة.

ما الاختبارات التي تُجرى على دفعات الإنتاج؟
يتبع الاختبار المواصفات المتفق عليها عند تجميد التصميم: تحمل العازل (hipot)، ومقاومة العزل، والفحص الأبعادي، والفحص البصري للطلاء وغلق الحواف، وفحوص الاستمرارية لكل مسار موصل.
هل يمكنكم توفير وثائق لنظام الجودة لدينا؟
تُحتفظ بسجلات الاختبار الأبعادي والكهربائي لكل دفعة. إذا كان نظام الجودة لديك يتطلب شهادات مطابقة (CoCs) أو صيغًا محددة أو وثائق بنمط PPAP، فأخبرنا بها عند مرحلة التسعير ونوافق الأوراق مع متطلباتك.
هل تدعمون النماذج الأولية منخفضة الكمية قبل الإنتاج؟
نعم. تشمل المشاريع المخصصة عادةً: مراجعة المواصفات، وDFM، والتسعير، وتصنيع العينة للتحقق من الملاءمة والكهرباء، ثم إنتاج بالأدوات مع رقابة جودة موثقة لكل دفعة.
ما صيغ الملفات التي تقبلونها للمخططات؟
نقبل ملفات PDF وDXF وSTEP، إضافة إلى صور القطع الموجودة. تكفي المخططات ثنائية الأبعاد بالأبعاد والتفاوتات للتسعير؛ أما النموذج ثلاثي الأبعاد فيسرّع مراجعة DFM وتجهيز الأدوات.
هل تقدمون ضمانًا على قضبان التوصيل لديكم؟
نعم. القطع مشمولة ضد عيوب المواد والتصنيع لفترة الضمان المتفق عليها في اتفاقية الشراء. تُعاد معالجة أي قطع غير مطابقة أو تُستبدل، مع مشاركة تحليل الأعطال عند الطلب.
هل تدعمون الشحن والتغليف الدولي؟
نعم. تُعبأ القطع بحماية للحواف، وغشاء مضاد للكهرباء الساكنة، وكراتين للتصدير وفق متطلبات مناولتك، وتُشحن بحرًا أو جوًا. تُرفق المستندات التجارية (الفاتورة، قائمة التعبئة، سجلات الاختبار) مع كل شحنة.

Need test records with your shipment?

Tell us at quotation stage — we align CoCs, PPAP-style documentation and test records with your quality system.