月~金 9:00–18:00 · 中国標準時(UTC+8)· 山東省・中国
Case Study · Rail / Traction

Traction Converter Busbar: 1800 V Isolation Meets IEC 61373 Vibration

RailVolt Traction Systems, an Indian rolling-stock supplier, engaged SHANYUAN for the traction converter DC-link busbar of a new regional locomotive. The part — 1800 V isolation, 2500 A continuous, designed to IEC 61373 category-2 vibration — completed type testing in 2025 and entered series production for 120 locomotives in 2026, with a 20-year service life target.

ByNadia Rahman Rail / Traction Customer Case Study
Customer & Project

Project at a Glance

RailVolt Traction Systems Pvt. Ltd. Rail / Traction India · Regional and freight locomotives Locomotive traction converter laminated busbar Delivered 2025–2026

This case study is published as a representative engineering project. The product photograph and released drawing are illustrative of the delivered part; exact dimensions are covered by the customer's non-disclosure agreement.

Engineering 図面s

Released 図面

Engineering drawing for RailVolt Traction — Locomotive traction converter laminated busbar
Released drawing excerpt
Engineering drawing for RailVolt Traction — Locomotive traction converter laminated busbar
Released drawing excerpt

Customer drawings are treated as confidential; excerpts shown here are provided with permission and illustrate the layer stack, terminal layout and dielectric boundaries of the delivered part.

Product Photograph

The Delivered Part

Laminated busbar delivered for RailVolt Traction — Locomotive traction converter laminated busbar
Representative product photograph of the delivered laminated busbar — insulated stack, terminals and dielectric finish as released for production.
Specifications

Project Parameters

Customer & platformRailVolt regional locomotive traction converter, 2500 A DC-link
Busbar typeMulti-layer laminated DC-link busbar, C11000 copper, 2.5 mm conductors
Dielectric systemNomex + epoxy, 1800 V isolation, PD-free to 1.2 kV
定格電流2500 A continuous, 4000 A 2 min
温度上昇ΔT 28 °C at rated current, 70 °C ambient
VibrationIEC 61373 category 2, 3 axes, 5 h each
TerminalsM12 studs for IGBT press-packs, blade for capacitor bank
Production120-locomotive program, 100% hi-pot and inductance scan
Quantified result1800 V isolation, cat-2 vibration pass, 28 °C ΔT, 2500 A

RailVolt Traction Systems, an Indian rolling-stock supplier, engaged SHANYUAN for the traction converter DC-link busbar of a new regional locomotive. The part — 1800 V isolation, 2500 A continuous, designed to IEC 61373 category-2 vibration — completed type testing in 2025 and entered series production for 120 locomotives in 2026, with a 20-year service life target.

The challenge: rail vibration plus 2500 A in a tight converter bay

RailVolt's new regional locomotive uses a 2500 A traction converter with IGBT press-pack modules. Two constraints dominated the busbar design: the converter bay's mechanical envelope left only 40 mm for the DC-link interconnection, and the equipment must survive IEC 61373 category-2 vibration — the most severe rolling-stock environment — without joint fatigue over a 20-year life.

The customer specified 1800 V isolation for the DC-link (covering the catenary transient envelope of the regional network), PD-free operation to 1.2 kV, and a busbar that could be serviced without removing the converter from the locomotive.

SHANYUAN's design review applied the vibration and bolted-joint guide and the rail traction converter article, which covers the DC-link architecture used by modern regional locomotives.

The solution: Nomex-insulated stack with vibration-proof joints

The delivered busbar stacks three conductor pairs with Nomex insulation and epoxy edge sealing, sized for 1800 V isolation with a 20 mm creepage path across the sealed edge. All eight IGBT press-pack connections sit on M12 studs with Belleville washer stacks that maintain preload under vibration — the retention method documented in the vibration guide.

Joint design uses the multi-point contact pattern from the connections guide; each module connection has redundant contact area so a single point's relaxation never breaks the circuit. The capacitor bank connects through blade terminals welded to the stack.

The complete part fits the 40 mm bay envelope with 6 mm clearance to the housing, using the layer-count logic in the layer-count selection guide.

Thermal and dielectric engineering

Temperature-rise testing at 2500 A in a 70 °C ambient chamber measured 28 °C rise with the hot spot on the capacitor tabs — inside the 30 °C budget. The thermal management guide documents the forced-air cooling assumptions used for the converter bay.

Nomex 410 was selected over PET for the higher short-term thermal margin during 4000 A overload and for its better dielectric consistency across the 20-year life. The insulation system passed a 4.5 kV hi-pot, PD-free to 1.2 kV, and 1000 thermal cycles from −40 °C to +125 °C. Dielectric selection rules are covered in the design guide and the partial-discharge resource.

Creepage and clearance follow the rail converter voltage class with the margins published in the ampacity chart reference tables.

Type testing and series production

Type testing ran at the customer's rail test laboratory: IEC 61373 category-2 vibration (3 axes, 5 hours each), thermal cycling, 4.5 kV hi-pot and PD verification. All passed on the first submission; the vibration test showed no measurable joint-resistance drift after 15 g random excitation.

Series production serves the 120-locomotive program at a rate aligned with the customer's converter build: 100% hi-pot and inductance scan per part, with per-batch dossiers from the quality laboratory. The factory tour shows the lamination and hi-pot stations used.

The program's quality plan follows the IATF-adjacent automotive discipline our team runs; the manufacturing process article explains the full production chain from stamping to final test.

Quantified results

The busbar met every target: 1800 V isolation, PD-free to 1.2 kV, 2500 A continuous with 28 °C rise, IEC 61373 category-2 vibration pass, and 20-year service life engineering.

Two locomotive prototypes have accumulated 60 000 km in trial service with zero busbar-related faults, and the customer reports that the converter bay assembly time dropped by 20 minutes per unit compared with the previous bolted-bar design.

For rail traction engineers, the rail and traction application page, the power electronics busbar range and the engineering contact form are the practical starting points.

Isolation1800 V, PD-free to 1.2 kV
Current2500 A continuous / 4000 A 2 min
ΔT at rating28 °C @ 70 °C ambient
Service60 000 km trial, zero faults
よくある質問

Frequently asked questions

How does the busbar survive 20 years of rail vibration?
M12 studs with Belleville washer stacks maintain preload under vibration, and each module connection has redundant multi-point contact area. The design passed IEC 61373 category-2 testing with no measurable joint-resistance drift.
Why Nomex instead of PET on a traction converter?
Nomex gives higher short-term thermal margin for the 4000 A overload and better dielectric consistency over the 20-year life, with 1800 V isolation and PD-free operation to 1.2 kV.
How is the part serviced in the locomotive?
The busbar fits the 40 mm converter bay envelope and can be accessed without removing the converter from the locomotive; all connections are M12 studs with documented torque values.
関連

続きを読む

SiCが鉄道へ:2026年プログラム向け牽引コンバータDCリンクバスバー設計
鉄道・モビリティ

SiCが鉄道へ:2026年プログラム向け牽引コンバータDCリンクバスバー設計

鉄道牽引へのSiC採用が進む。高周波スイッチングと車載環境がDCリンクに求める低インダクタンス・耐振設計を解説。

記事を読む
振動下のバスバー・ボルト接合:締付力・熱サイクル・機械設計
機械設計

振動下のバスバー・ボルト接合:締付力・熱サイクル・機械設計

振動環境で緩まないボルト継手。適正締付力、ばね座金、熱サイクルによる接触抵抗変化と設計上の注意点を解説。

記事を読む
Nadia Rahman
Nadia Rahman品質・コンプライアンスエンジニア

Nadia Rahmanは品質・コンプライアンスエンジニアで、電機部品の品質システムに9年の経験があります。SHANYUANのISO 9001およびIATF 16949プログラム、受入・出荷検査、UL/IECコンプライアンス文書を管理しています。バーミンガム大学で工業工学の学士号を取得。バスバー品質管理と輸出向けコンプライアンス文書について執筆しています。

ISO 9001ULコンプライアンス品質管理
プロフィール全文を見る

この用途向けにバスバーを設計中ですか?

電流プロファイル・電圧クラス・端子タイプをお送りください — 1営業日以内にエンジニアが回答します。